フィルムコンデンサの容量と耐圧

Film Capacitor and Voltage rating

2026-07-31 / Reference

Reading Film Capacitor Markings

Most builders already know this, but it’s worth taking a quick look at how film capacitors are marked.

Film capacitors

The marking “472J100” consists of three digits, a tolerance letter, and the voltage rating.

The first three digits represent the capacitance. The third digit is the power of ten, and the unit is picofarads (pF).

47 × 10² pF = 4700 pF = 4.7 nF

The letter indicates the tolerance: F = ±1%, G = ±2%, J = ±5%, K = ±10%, and M = ±20%. The final number is the voltage rating, which is 100 V in this example.

For example, “101” means 10 × 10¹ pF, or 100 pF.

Some capacitors are marked directly with values such as “4.7n”. Others use notations like “1n2”, “6n8”, or “2u2”, which mean 1.2 nF, 6.8 nF, and 2.2 µF respectively. Using the unit letter instead of a decimal point makes the marking easier to read on small components.

Voltage Ratings

Voltage ratings matter much more for capacitors than for resistors. An electrolytic capacitor connected with reverse polarity or operated beyond its voltage rating can fail quite dramatically—and the smell is unforgettable.
Large capacitors used in tube amplifiers deserve even more respect.

The 100 V printed on a capacitor almost always refers to its DC voltage rating. Household mains voltage, however, is AC. A 100 VAC supply has a peak voltage of about 141 V and a negative peak of about -141 V, giving approximately 282 V peak-to-peak.

waveform

The simulation uses a 50 Hz sine wave with a peak amplitude of 141 V. The waveform viewer displays several measurements. The displayed interval runs from 0 to 20 ms, which is exactly one cycle of a 50 Hz waveform.
A sine wave has a positive half-cycle and an equal negative half-cycle, so if you simply average the waveform, the positive and negative portions cancel each other out. As a result, the Average value is approximately 0 V. That doesn’t mean, of course, that the AC voltage has no effect.
This is where RMS (Root Mean Square) comes in. The RMS value is the equivalent DC voltage that would produce the same heating effect in a resistor. For this waveform, the RMS value is approximately 100 V. This is also what the “100 V” of Japanese household mains refers to. As a useful rule of thumb, the RMS value of a sine wave is simply its peak voltage divided by √2, so 141 V ÷ √2 ≈ 100 V.

You may not work directly with mains very often, but it’s important to remember that AC and DC voltage ratings are not interpreted in the same way.